    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Randomized Controlled Trial of Individualized Dialysate Cooling for Cardiac Protection in Hemodialysis Patients.

    Thumbnail
    Abstract
    BACKGROUND AND OBJECTIVES: Cardiovascular disease is the most common cause of death in patients on hemodialysis (HD). HD-associated cardiomyopathy is appreciated to be driven by exposure to recurrent and cumulative ischemic insults resulting from hemodynamic instability of conventionally performed intermittent HD treatment itself. Cooled dialysate reduces HD-induced recurrent ischemic injury, but whether this confers long-term protection of the heart in terms of cardiac structure and function is not known. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Between September 2009 and January 2013, 73 incident HD patients were randomly assigned to a dialysate temperature of 37°C (control) or individualized cooling at 0.5°C below body temperature (intervention) for 12 months. Cardiac structure, function, and aortic distensibility were assessed by cardiac magnetic resonance imaging. Mean between-group difference in delivered dialysate temperature was 1.2°C±0.3°C.Treatment effects were determined by the interaction of treatment group with time in linear mixed models. RESULTS: There was no between-group difference in the primary outcome of left ventricular ejection fraction (1.5%; 95% confidence interval, -4.3% to 7.3%). However, left ventricular function assessed by peak systolic strain was preserved by the intervention (-3.3%; 95% confidence interval, -6.5% to -0.2%) as was diastolic function (measured as peak diastolic strain rate, 0.18 s(-1); 95% confidence interval, 0.02 to 0.34 s(-1)). Reduction of left ventricular dilation was demonstrated by significant reduction in left ventricular end-diastolic volume (-23.8 ml; 95% confidence interval, -44.7 to -2.9 ml). The intervention was associated with reduced left ventricular mass (-15.6 g; 95% confidence interval, -29.4 to -1.9 g). Aortic distensibility was preserved in the intervention group (1.8 mmHg(-1)×10(-3); 95% confidence interval, 0.1 to 3.6 mmHg(-1)×10(-3)). There were no intervention-related withdrawals or adverse events. CONCLUSIONS: In patients new to HD, individualized cooled dialysate did not alter the primary outcome but was well tolerated and slowed the progression of HD-associated cardiomyopathy. Because cooler dialysate is universally applicable at no cost, the intervention warrants wider adoption or confirmation of these findings in a larger trial.
    URI
    https://orda.derbyhospitals.nhs.uk/handle/123456789/230
    Collections
    • Specialist Medicine [375]
    Date
    2015-08
    Author
    Odudu, Aghogho
    Eldehni, Mohamed
    Show full item record

    copyright © 2017  Derby Teaching Hospitals NHS Foundation Trust
    Contact Us | Send Feedback
    Powered by KnowledgeArc
     

     

    Browse

    All of ORDACommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    Researcher Profiles

    Researchers

    My Account

    Login

    copyright © 2017  Derby Teaching Hospitals NHS Foundation Trust
    Contact Us | Send Feedback
    Powered by KnowledgeArc